| Basic Performance | Working Medium | Industrial gases such as nitrogen, argon, and air, as well as low-viscosity hydraulic oil and water-based media; sealing and wetted materials can be selected according to medium properties |
| | Drive Method | Compressed air drive, no power supply required, suitable for explosion-proof environments |
| | Output Pressure | Meets requirements from conventional to high-pressure applications (gas up to XX MPa, liquid up to XX MPa); higher pressure levels can be customized based on operating conditions |
| | Pressure Accuracy | High-precision closed-loop control, meeting precision testing requirements |
| Control and Automation | Control Mode | Multi-channel independent control, each channel can be independently adjusted |
| | Control System | Industrial controller + human-machine interface, touch screen operation, data storage and export |
| | Remote Monitoring | Supports industrial communication protocols, enabling unattended operation and centralized management |
| | Pressure Adjustment | Constant-speed pressurization, stabilization, stepwise pressurization, meeting static pressure test and holding pressure test requirements |
| | Waveform Output | Multiple pressure waveforms output (sine wave, triangle wave, trapezoidal wave, etc.), used for dynamic fatigue testing and alternating pressure simulation |
| Flow Control | Flow Regulation | Independent flow regulation for each channel, flow control units (gas/liquid) can be configured according to medium and operating conditions |
| | Flow Range | Covers common flow ranges, can be selected according to actual needs |
| Safety Protection | Overpressure Protection | Double protection with software upper limit setting and independent safety valve, automatic depressurization/stop in case of unexpected overpressure |
| | Low Pressure Protection | Automatically locks when the driving gas pressure is insufficient, preventing abnormal equipment operation |
| | Leak Detection | System pressure-holding test function, optional leak alarm to ensure safe testing process |
| Physical Parameters | Structural Form | Mobile or fixed skid-mounted, customizable according to on-site space |
| | Air Source Requirement | Clean and dry compressed air (for driving); liquid medium needs to be self-provided by the user or equipped with a supply system |
| | Interface Size | High-pressure connectors configured according to pressure level, quick connectors can be configured according to customer requirements |